5-20 DL600E E1 Data Multiplexer UserÕs Guide
For more information about monitoring the DL600E unit, refer to ÒMenu-1
Main Status ParametersÓ
in Chapter 4.
Using the TEST Menu
You can perform the Self-Test, activate network loopbacks, test modes,
and
DTE loopbacks on the local DL600E unit from the front panel TEST
menu.
D
Note: The TEST menu does not appear on the front panel
display if the front panel is protected in Menu-4 Main
ConÞguration (
UNIT Protect mode is enabled).
Only the Network Loopback test can be run on the remote unit from the
TEST menu.
Starting and Ending a Test
You can run only one test at a time. To run another test, you must
terminate the first one.
1 To start a test, open the TEST menu and select the test from the
menu or one of the sub-menus.
If you select a test that applies to a fraction of the E1
bandwidth, you are prompted to specify the fraction.
MONITOR
CONFIGURATION
TEST
EFS 100 PERCENT